| Choose a system for more details: |
|
Calculators  |
|
Flow Meters  |
|
Packages  |
|
Sensors  |
|
|
|
|
|
|
|
|
|
|
|
Mechanical  |
|
Ultrasonic  |
|
Glycol  |
|
|
|
|
|
| Ultrasonic BTU Meter Packages: |
|
| Model # |
Description |
Metrima Part Component |
| TCTF2TDU |
3/4" Ultra. 1 l/p
English BTU-KW |
SVM-F21155-912-18T0 |
F2 Calculator English pulse 1 l/p |
| SVM-TDA26CC304T10 |
Temperature Sensor |
| SVM-V700-115-1-30 |
Flow Meter 3/4", Qp1.5, 1l/p |
| TT20B |
Tee for Temp. sensor |
| TCTMMS |
NPT adapters for Flow Meter and Tee |
|
|
| Model # |
Description |
Metrima Part Component |
| TCTF2TDU1 |
1" Utra. 2.5 l/p
English BTU-KW |
SVM-F21155-912-18T0 |
F2 Calculator English pulse 2.5 l/p |
| SVM-TL045CC304T10 |
Temperature Sensor |
| SVM-V700-415-1-30 |
Flow Meter 1",Qp 2.5, 2.5 l/p |
| TP34B |
Pocket for Temp sensor (Pair)34mm |
| Z3-NPT-02 |
NPT adapters for 1" Flow Meter |
|
|
| Model # |
Description |
Metrima Part Component |
| TCTF2TDU112 |
1.5" Ultra. 2.5 l/p
English BTU-KW |
SVM-F21115-910-18T0 |
F2 Calculator English pulse 2.5 l/p |
| SVM-TL045CC304T10 |
Temperature Sensor |
| SVM-V700-511-1-30 |
Flow Meter 1.5",Qp 3.5, 2.5l/p |
| TP50B |
Pocket for Temp sensor (Pair)50mm |
| Z3-NPT-04 |
NPT adapters for 1.5" Flow Meter |
|
|
| Model # |
Description |
Metrima Part Component |
| TCTF2TDU2 |
2" Ultra. 10 l/p
English BTU-KW |
SVM-F21165-910-18T0 |
F2 Calculator English pulse 10 l/p |
| SVM-TL045CC304T10 |
Temperature Sensor |
| SVM-V700-516-1-30 |
Flow Meter 2",Qp 10, 10 l/p |
| TP50B |
Pocket for Temp sensor (Pair)50mm |
| Z3-NPT-08 |
NPT adapters for 2" Flow Meter |
|
|
|
|
|
| Technical Overview: |
|
F2 CALCULATOR |
|
| Flow Sensors (with pulse output) |
Max. Frequency
Min. Pulse Length
Max. Voltage
Max. Cable Length |
12 Hz
40 ms
3 V
49.2 ft |
|
| Temperature Sensors |
Max. Cable Length
Max. Sensor Current |
8.2 ft at 31 gauge cable area
16.4 ft at 24 gauge cable area
24.6 ft at 21 gauge cable area
49.2 ft at 15 gauge cable area
4 mA (RMS) for Pt 100 |
|
| Power Supply |
Battery
|
3V - 2.2 Ah
10 Year Design Life
|
|
|
| Temperature |
Range
Difference
|
32 - 374° F
2 - 100 K |
|
| Data Output |
M-Buss (EN1434-3)
|
Via OPTO-interface (EN60870-5) and via bus connection (terminal) |
|
| Pulse Outputs (Open Collector) |
Pulse Length
Max. Voltage
Max. Current |
250 ms
30 V
20 mA |
|
| Ambient Temperature |
Operation
Storage/Transport
|
+41° F to +131° F
-4° F to +158° F |
|
| Pulse Inputs |
Max. Frequency
Min. Pulse Length
Max. Voltage |
12 Hz
40 ms
3 V |
|
| Protection Class IP54 |
| Environmental class C according to EN1434 |
. |
|
| Alarm Output (Open Collector) |
| Pulse Length
|
250 ms
|
|
|
|
V700 FLOW METERS |
|
TL0/TDA SENSORS |
|
|
|
| Adapters |
(Included) BPT to NPT |
Flow [gal/m]
Maximum flow
Normal flow
Minimum flow |
.
13.2 - 30.8
6.60 - 15.4
0.07 - 0.15
|
Dimensions
Length [in]
Height [in]
Weight [lb] |
.
4.3 - 10.2
3.0 - 4.8
2.2 - 6.6
|
| Maximum temperature |
266 [ºF] |
| Meteorological class |
1:100 |
|
|
| Adapters |
Pt100/Pt500 |
| Resistance according to |
IEC751 |
| Max RMS sensor current |
8 [mA] |
| Measuring range |
32 - 284 [ºF] |
| Tolerance |
Class B |
| Max. Temperature Difference |
35.6 - 212 [ºF] |
| Temperature step response |
1.8 [s] |
| Min. immersion depth |
.79 [in] |
| Pressure class |
PN16 |
Dimensions
Diameter [in]
Length [in] |
.
0.20
1.02 |
| Sensor tube material |
Inconel® |
| Resistance (2-wire cable) |
2955 [Ω] |
| Standard Cable length |
6.56 [ft] |
| Cable type |
Silicone, PUR or PVC |
|
|
|
|
|
|
|